Dimetix FLS-C

FLS-C     for fast measuring and unique accuracy 500m    +  1.0 mm
The FLS-C distance measuring device measures absolute distances up to 500 meters without contact and with an accuracy of 1.0 millimetres.  It represents a cost-effective solution even at extreme ambient temperatures as low as -40° C using the optional heater. The FLS-C has been designed to be suitable for both heavy industrial and outdoor applications.  It is constructed of a solid metal case and provides class IP65 environmental protection.  Furthermore, various features make it flexible for multiple applications in numerous industries such as automotive, paper, metal and textile.
Highlights

  • Measuring range 0.05 to 500 m
  •  1.0 mm accuracy
  • Serial interface (RS232 and RS422)
  • High precision analogue output (0.1%)
  • Two programmable digital outputs
  • Digital output for error signalization
  • Profibus interface
  • SSI Interface
  • D-Sub connector and screw terminal for easy connection
  • Solid metal enclosure IP65
  • Wide temperature range: -40 … +50 °C
IMGP0997small Dimetix FLS C

 

 

Important Technical Data

FLS-C10

FLS-C30

FLS-CH10

FLS-CH30

Part Number

600502

600501

600504

600503

Typical measuring accuracy

±1.0 mm

±3.0 mm

±1.0 mm

±3.0 mm

Typical repeatbility

±0.3 mm

±0.5 mm

±0.3 mm

±0.5 mm

Typical measuring range on
natural surfaces

0.05 to 65 m

0.05 to 65 m

0.05 to 65 m

0.05 to 65 m

Typical measuring range on reflecting
target plate

0.5 to 500 m

0.5 to 500 m

0.5 to 500 m

0.5 to 500 m

Measuring rate (Up to)

200 Hz

200 Hz

200 Hz

200 Hz

Diameter laser dot
▪ 10 m

8 mm

8 mm

8 mm

8 mm

▪ 50 m

25 mm

25 mm

25 mm

25 mm

▪ 100 m

40 mm

40 mm

40 mm

40 mm

Power Supply

9V … 30 VDC

9V … 30 VDC

24V … 30 VDC

24V … 30 VDC

Power Consumption

max. 0.6A@24 V

max. 0.6A@24 V

max. 2.5A@24 V

max. 2.5A@24 V

Temperature range
▪ Operation Single measurement

-10°C to 50°C

-10°C to 50°C

-40°C to 50°C

-40°C to 50°C

▪ Operation Continuous measurements

-10°C to 45°C

-10°C to 45°C

-40°C to 45°C

-40°C to 45°C

▪ Storage

-40°C to 70°C

-40°C to 70°C

-40°C to 70°C

-40°C to 70°C

Downloads:

DLS_FLS_C_TechnicalManual_V502_en

DLS_FLS_C_TechnicalManual_V204_en

adminDimetix FLS-C